Eagle ® ICS System – Unicard CR211 User & Installation Instructions Page 4 of 17
Relay 1 : is normally used to open the door.
Relay 2 : could be used for different functions :-
Alarm shunt, alarm panel on/off, duress alarm, open a second
door, manipulation blocking alarm, control a electronic lock / strike
or a door bell. Monostable relay function is normally used for door
opening, alarm shunt, duress alarm, door open alarm and blocking
alarm while bistable relay function is used for alarm on/off, and
door open during the day.
NB
If the duress output is connected to a monitored intruder
alarm, please check compliance to relevant Police Force
policy.
Alarm function 8 : Controls the relationship and operation of relays
1 & 2.
The disable functions are:
< 0 > - No time control
< 1 > - Card disabled if PL2:19 PL2:20 is open circuit.
< 2 > - Card disabled if PL2:19 PL2:20 is closed
circuit.
User cards are programmed as follows :-