Eagle Access Control Systems Eagle-E7 Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 17
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
Eagle ® ICS System – Unicard CR211 User & Installation Instructions Page 2 of 17
Unicard has four LED’s. The green LED indicates relay 1. The
yellow LED indicates key depression and also requests the PIN-
code (when the unit is set to card & PIN). The first red LED
indicates access denied and the second one is free for external
control via inputs on PL4: 11,12.
NB
There is a 560 resistor in series with the second red LED,
this value is suitable for 12VDC supply. If you are to use
24VDC cut the S3 jumper in the unit.
2. Initialisation & Password
After installation the Unicard has to be initialised with a special
code. This code pre-sets printer parameters, clears the memory
and sets the opening times to 7 seconds. The code is 199201.
Initialisation & Memory Reset
I
Open the card reader
Press RST button on the
circuit board
Wait for 4 bleep confirmation
Enter 199201
Press #
Wait for 8 bleep confirmation,
the memory is now cleared and
language is set to English.
NB
If the print out is printed in a language other than English, an
incorrect initialisation code has been entered. Repeat the
above instructions.
To allow the reader to be programmed and to initiate the printouts
a six digit password is required.